beautypg.com

Subdrive, Installation procedure, Wiring connection – Flint & Walling Commander Pro 75 User Manual

Page 7: Cp water controller

background image

7

95 North Oak Street • Kendallville, IN 46755

Copyright 2012. All Rights Reserved.

INSTALLATION PROCEDURE

1. Disconnect electrical power at the main breaker
2. Drain the system (if applicable)
3. Install pressure sensor. The pressure sensor has a

1/4-18 National Pipe Thread (NPT) connection.

4. Use Figure 7 as a guide to locating drill holes into

the wall. Remove the CP WATER Subdrive cover by

removing the three lid screws. Install the unit to the

wall using the three mounting screws (not included).

WIRING CONNECTION

Serious or fatal electrical shock may

result from failure to connect the ground terminal to the

motor, CP WATER Subdrive controller, metal plumbing or

other metal near the motor or cable, using wire no smaller

than motor cable wires. To minimize the risk of electric

shock, disconnect power before working on or around the

CP WATER Subdrive system.

CAPACITORS INSIDE THE CP

WATER SubDrive CONTROLLER CAN STILL HOLD A

LETHAL VOLTAGE EVEN AFTER POWER HAS BEEN

DISCONNECTED.

ALLOW 10 MINUTES FOR DANGEROUS

INTERNAL VOLTAGE TO DISCHARGE BEFORE REMOVING

CP WATER COVER.

DO NOT USE MOTOR IN SWIMMING AREA.

1. Verify that the power has been shut off at the main

breaker.

2. A circuit breaker must be availalbe for the Subdrive.

Wire from the supply panel to the Subdrive must be the

correct size.

Model

Circuit

Breaker

Wire Size

Subdrive 75

15-Amp

14 AWG or larger

Subdrive 100

20-Amp

12 AWG or larger

Subdrive 150

25-Amp

10 AWG or larger

3. Remove the CP WATER Subdrive lid.
4. Feed the motor leads through the opening on the

bottom right side of the unit and connect them to the

terminal block positions marked (green ground wire),

Red (Black) Yellow (Brown) and Black (Blue).

5. Feed the 230V power leads through the large opening

on the bottom left side of the CP WATER Subdrive

controller and connect them to the terminals marked

L1, GND, and L2.

6. Feed the pressure sensor leads through the smaller

opening on the bottom left side of the CP WATER

SubDrive unit and connect the red and black leads to

the terminals marked “1” and “2” (interchangeable) with

a small screwdriver (provided).

7. Use the appropriate strain relief or conduit connectors.
8. Replace the cover. Do not over-tighten the screws.
9. Connect the other end of the pressure sensor cable

with the two spade terminals to the pressure sensor.

The connections are interchangeable. (Figure 8)

Pump

Motor

1

2

POWER ON

FAULh

C O N STA NT P R E S S U R E P U M P I N G SY ST E M

1

2

Black

Red

L1

L2

SubDrive

IL0878

Mounting Screw Location

From

Power

Source

(Input)

Mounting

Screw

Location

Mounting

Screw

Location

Output

To Motor

Red Yel Blk

(Blk)(Brn)(Blu)

(Output)

Power Supply

From Circuit Breaker

Drain

Valve

To Discharge

*Pressure

Relief Valve

To

Residence

Pressure

Gauge

Pressure

Sensor

Pressure Tank

Inflation Valve

Pressure Tank

CP Water Controller

Figure 7

This manual is related to the following products: