beautypg.com

Pump electrical connections, Fig 2 fig 1, Fig 4 fig 3 – Flint & Walling SP Self-Priming Sprinkler Pump User Manual

Page 8: Fig 6 fig 5

background image

8

© Copyright 2014 Flint & Walling. All rights reserved.

PUMP ELECTRICAL CONNECTIONS

A

B

L2

L1

IL1271

Fig 2

Fig 1

A

B

L2

L1

IL1272

A

B

L2

L1

IL1273

Fig 4

Fig 3

A

B

L2

L1

IL1274

A

B

L2

L1

GRAY

RED

Fig 6

Fig 5

A

B

L2

L1

GRAY

RED

A

B

L2

L1

GRAY

RED

Fig 7b

Fig 7a

Fig 7c

1. Remove rear motor cover on pump by

unscrewing the two screws.

2. Thread electric wire strain relief into wire

opening on the side of the motor of pump.

3. Insert wire through electric wire strain relief

and tighten screws.

4. Connect white power lead to L1 and black

power lead to L2.

5. Connect green ground wire to green

grounding screw. Re-install rear motor cover

to pump.

To change from 230 V to 115 V
6. The motor of pump is dual voltage and

can run on either 115 volts or 230 volts. In

general, 230 volts is more economical to run,

and requires a smaller wire size. The pump is

pre-set in the factory to run at 230 volts.

7. For 115 volts service, change the following

wires on the terminal board:

a. Using a pair of needle nose pliers, pull the

gray wire with the female flag connector

from the “B” terminal spade post. Place it

to the left on the “A” terminal space post.

b. Pull the red wire with the female flag

connector from the “B” terminal. Place it to

the right on the L2 terminal space post.

c. Reinstall the rear motor cover.