PUMP INSTALLATION FOR WELL AND SURFACE WATER

1. Mount pump on a solid foundation as close to

the water source as possible.

CAUTION: Support the 2 in. inlet

pipe from the well or lake to the inlet port

to prevent sagging. Sagging will create air

pockets within the pipe that will prevent the

pump from priming and operating correctly.

2. Glue female 2 in. union to the end of inlet

pipe leading from the water source.

3. Connect the 2 in. union together to complete

the inlet line to the pump.

4. Glue a 6 in. piece of 1-1/2 in. pipe to the

female portion of the 1-1/2 in. union.

5. Glue 1-1/2 in. ball valve to the other end of

the 6 in. piece of pipe.

6. Connect the 1-1/2 in. outlet pipe to the

sprinkler system by gluing in additional

sections of pipe as needed.

7. Connect union to ensure proper fit. Do not

tighten until after priming.

CAUTION: Do not glue union together.

Water Level

Discharge to

Sprinkler System

Well Seal

100 PSI

Pressure

Gauge

Priming Plug

Union

Ball

Valve

Outlet

Pipe

Inlet

Pipe

Well

Union

Water

Level

Outlet Pipe

Inlet

Pipe

2 in.

Female

Union

Fig 2

Fig 1

Water

Level

Outlet Pipe

Inlet

Pipe

2 in.

Union

1-1/2 in.

Union

Fig 4

Fig 3

Ball Valve

IL1123

Outlet Pipe

Inlet

Pipe

Discharge to

Sprinkler System

Fig 6

Fig 5

IL1124

Outlet Pipe

Inlet

Pipe

Discharge to

Sprinkler System