Flint & Walling SP Self-Priming Sprinkler Pump User Manual

Page 3

background image

3

© Copyright 2014 Flint & Walling. All rights reserved.

Typical Pump Setup

Typical setups for lawn sprinkler pump systems

include ground water wells (

Fig. 1) or surface

water, such as lakes, ponds or streams. (

Fig. 3)

Location

For best performance, the pump must be located

as close to the water source as possible and

protected from the elements.
Ventilation

Ventilation and drainage must be provided to

prevent damage to the motor from heat and

moisture.
Freezing

The pump and all piping must be protected from

freezing. If freezing weather is forecast, drain

pump or remove completely from the sprinkler

system.
Water Supply

The water source must be able to supply enough

water to satisfy the capacity of the pump and

water needs. See performance chart.

WARNING: NEVER run pump against a

closed discharge. Doing so can boil water inside

pump, causing hazardous pressure in unit, risk

of explosion and possibly scalding persons

handling pump. (

Fig. 2)

Vertical Lift

Vertical lift is the vertical distance from the lowest

level of the water to the pump intake. The pump

will move water as long as the pump is within 25

vertical feet of the water source.
Horizontal Distance

The horizontal distance is the horizontal

measurement between the pump inlet and the

water source. This distance may affect the ability

of the pump to operate. If it is over 150 feet, call

customer service at 1-866-994-4148.
Pipe And Fittings

Use galvanized steel or NSF PW Schedule 40

PVC pipe and fittings. This material is designed

for water pressure and will seal against air

and water under pressure. Do Not Use: DWV

fittings, as these are designed for drains without

pressure and will not seal properly.

GENERAL PUMP INFORMATION

Water Level

25 ft.

max

Vertical

Lift

Outlet

Pipe

Inlet

Pipe

Discharge to

Sprinkler System

60 ft. max.

Inlet pipe to water

Pipe

Support

Fig 2

Fig 1

Water Level

25 ft.

max

Vertical

Lift

Outlet Pipe

Inlet

Pipe

Discharge to

Sprinkler System

Inlet pipe to water

Pipe

Support

60 ft. max.

Motor Cover

Foot

Valve

Fig 3

CAUTION: The entire system must be

air and water tight for efficient operation and to

maintain prime.
Wire Size:

The wire size is determined by the distance from

the breaker box to the pump motor, and the

horsepower rating of the motor. See the wire chart

for proper wire size.

1-1/2 in. Discharge

2 in.

Suction

Fig 4