beautypg.com

EUCHNER CETx-AP-xxx-AH-xxx (Unicode) User Manual

Page 21

background image

Operating Instructions Safety Switch CET.-AP-...-AH-...

21

wiring diagram A

Plug connectors

(view of connection side)

PIN

Designation

Function

Wire color

Connection cable

1)

Door monitoring

output

with

without

2 x M12

S2.5

S1.8

S1.5

S1.6

S1.7

S1.2

S2.4

S2.3

S2.1

S2.2

S1.4

S1.3

S1.1

S 1.1

-

n.c.

WH

S 1.2

U

B

Operating voltage, 24 V DC

BN

S 1.3

OA

Safety output, channel 1

GN

S 1.4

OB

Safety output, channel 2

YE

S 1.5

OUT

Door monitoring output

GY

S 1.6

-

n.c.

PK

S 1.7

0 V U

B

Operating voltage, 0 V

BU

S 1.8

RST

Reset input

RD

S 2.1

0 V U

CM

Operating voltage of guard locking solenoid 0 V

BN

Depending on version

S 2.2

LED 1

LED 1 red, freely configurable

 2)

, 24 V DC

WH

OUT D

Door monitoring output (only CET3-AP and CET4-AP)

S 2.3

LED 1

LED 2

LED 1 red or LED 2 green, freely configurable

 2)

, 24 V DC

BU

S 2.4

U

CM

Operating voltage of guard locking solenoid, 24 V DC

BK

S 2.5

J

Version with teach-in input: 

To teach-in a new actuator, connect to 24 V DC; in nor-

mal operation connect to 0 V.

GY

Y

Version with feedback loop:

If the feedback loop is not used, connect to 24 V DC

B

-

Version without feedback loop and without teach-in input: 

This connection must be connected to 0 V.

1) Only for standard EUCHNER connection cable

2) Can vary depending on version. See data sheet.

wiring diagram B

Plug connectors

(view of connection side)

PIN

Designation

Function

Wire color

Connection cable

1)

2 x M12

S2.5

S2.4

S2.3

S2.1

S2.2

S1.5

S1.4

S1.3

S1.1

S1.2

S 1.1

U

B

Operating voltage, 24 V DC

BN

S 1.2

OA

Safety output, channel 1

WH

S 1.3

0V

Operating voltage, 0 V

BU

S 1.4

OB

Safety output, channel 2

BK

S 1.5

-

n.c.

GY

S 2.1

-

n.c.

BN

S 2.2

-

n.c.

WH

S 2.3

0V UCM

0V solenoid

BU

S 2.4

UCM

Operating voltage of guard locking solenoid, 24 V DC

BK

S 2.5

-

n.c.

GY

1) Only for standard EUCHNER connection cable

2) Can vary depending on version. See data sheet.

Connector assignment of safety switch CET-AP with

2 x M12 plug connectors, 5-pin and 8-pin

Connector assignment of safety switch CET-AP for

connection to decentralized peripheral systems (2x

M12, 5-pin, pin 5 not used)