beautypg.com

Devices for direct connection ip65 field modules, Safety in case of faults, Fuse protection for power supply – EUCHNER CETx-AP-xxx-AH-xxx (Unicode) User Manual

Page 19

background image

Operating Instructions Safety Switch CET.-AP-...-AH-...

19

Devices for direct connection IP65 field modules

The version CET.-AP-...-SI-... (connection plan B) is optimized for connection to 

decentralized peripheral systems, such as the ET200pro series from Siemens. 

The devices are assigned parameters and connected like an OSSD (e.g. like light 

curtains).
The two 5-pin M12 plug connectors can be connected directly to the sockets of 

an IP65 field module (e.g. ET200pro) with the aid of the connection cables on 

Page 33. If flying leads are used, connection to IP20 input and output modules (e.g. 

ET200s) is naturally also possible.

Important:

Observe the following notes prior to connection:

 Ì

Use only CET-AP versions that are listed in the ordering table on Page 33.

 Ì

The operating voltage for the CET-AP must not be clocked. Parameter as-

signment might be required for the input/output modules (see application 

example at www.EUCHNER.de, in the area Download » Applications » CET).

 Ì

Additionally observe notes from the control system manufacturer where nec-

essary.

Safety in case of faults

 Ì

The operating voltage U

B

 and the solenoid voltage U

CM

 are reverse polarity pro-

tected. 

 Ì

The contacts OA/OB are short circuit proof.

 Ì

A short circuit between OA and OB is detected by the switch. 

 Ì

A short circuit in the cable can be excluded by laying the cable with protection. 

Fuse protection for power supply

The power supply must be provided with fuse protection depending on the current 

required for the outputs. The following rules apply:
Max. current consumption I

max

I

max

   = I

UB

 + I

OUT

* + I

OA+OB

 (+ I

OUT D

*)

I

UB

   = Switch operating current (80 mA)

I

OUT

   = Load current of monitoring outputs (max. 50 mA per monitoring output)

I

OA+OB

 = Load current of safety outputs OA + OB (2 x max. 200 mA)

* Only on devices with the corresponding monitoring output