beautypg.com

Technical data, Technical data for safety switch ces-i-ar-u-c04 – EUCHNER CES-I-AR-U-C04 (Unicode) User Manual

Page 24

background image

Operating Instructions Safety Switch CES-I-AR-U-C04

24

Technical data

Note!

If a product data sheet is included with the product, the information on the data

sheet applies in case of discrepancies with the operating instructions.

Technical data for safety switch CES-I-AR-U-C04

Parameter

Value

Unit

min.

typ.

max.

Housing material

Plastic PBT

Dimensions

42 x 25 x 18

mm

Mass (without connection cable)

0.05

kg

Ambient temperature

-25

-

+ 65

°C

Connection

- Plug connector M8, 8-pin or

- Connection cable PUR, 0.14 mm², with plug connector M12,

8-pin, or

- Connection cable PUR with flying lead, 8 x 0.14 mm²

Degree of protection

IP67

IP69K (only version with plug connector M8 and mating connec-

tor with the same degree of protection)

Safety class

III

Degree of contamination

3

Installation position

Any

Installation method

non-flush

Operating voltage UB (reverse po-

larity protected, regulated, residual

ripple < 5%)

24 ± 15% (PELV)

V DC

Current consumption max.

without load

35

mA

External fuse

(operating voltage)

0.25

-

8

A

Safety outputs FO1A/FO1B

Semiconductor outputs, p-switching, short circuit-proof

- Output voltage

U(FO1A)/U(FO1B)

1)

V DC

HIGH

U(FO1A)

U

B

-1.5

-

U

B

HIGH

U(FO1B)

LOW

U(FO1A)/U(FO1B)

0

-

1

Switching current per safety output

1

-

200

mA

Utilization category

according to EN IEC 60947-5-2

DC-13 24 V 200 mA

Caution: outputs must be protected with a free-wheeling diode in

case of inductive loads.

Off-state current I

r

0.25

mA

Monitoring output OD

Semiconductor output p-switching, short circuit-proof

- Output voltage

0.8 x U

B

-

U

B

V DC

- Max. load

-

-

50

mA

Rated insulation voltage U

i

-

-

300

V

Rated impulse withstand voltage U

imp

-

-

1.5

kV

Resilience to vibration

In acc. with EN IEC 60947-5-2

Switching frequency

-

-

1

Hz

Repeat accuracy R

10

%

EMC protection requirements

In accordance with EN IEC 60947-5-3 and EN IEC 61326-3-1

Reliability values acc. to EN ISO 13849-1
Category

4

Performance Level

PL e

PFH

d

4.1 x 10

-9

/ h

Mission time

20

years

1) Values at a switching current of 50 mA without taking into account the cable length.