Technical data, Technical data for safety switch ces-i-ar-u-c04 – EUCHNER CES-I-AR-U-C04 (Unicode) User Manual
Page 24

Operating Instructions Safety Switch CES-I-AR-U-C04
24
Technical data
Note!
If a product data sheet is included with the product, the information on the data
sheet applies in case of discrepancies with the operating instructions.
Technical data for safety switch CES-I-AR-U-C04
Parameter
Value
Unit
min.
typ.
max.
Housing material
Plastic PBT
Dimensions
42 x 25 x 18
mm
Mass (without connection cable)
0.05
kg
Ambient temperature
-25
-
+ 65
°C
Connection
- Plug connector M8, 8-pin or
- Connection cable PUR, 0.14 mm², with plug connector M12,
8-pin, or
- Connection cable PUR with flying lead, 8 x 0.14 mm²
Degree of protection
IP67
IP69K (only version with plug connector M8 and mating connec-
tor with the same degree of protection)
Safety class
III
Degree of contamination
3
Installation position
Any
Installation method
non-flush
Operating voltage UB (reverse po-
larity protected, regulated, residual
ripple < 5%)
24 ± 15% (PELV)
V DC
Current consumption max.
without load
35
mA
External fuse
(operating voltage)
0.25
-
8
A
Safety outputs FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage
U(FO1A)/U(FO1B)
1)
V DC
HIGH
U(FO1A)
U
B
-1.5
-
U
B
HIGH
U(FO1B)
LOW
U(FO1A)/U(FO1B)
0
-
1
Switching current per safety output
1
-
200
mA
Utilization category
according to EN IEC 60947-5-2
DC-13 24 V 200 mA
Caution: outputs must be protected with a free-wheeling diode in
case of inductive loads.
Off-state current I
r
≤
0.25
mA
Monitoring output OD
Semiconductor output p-switching, short circuit-proof
- Output voltage
0.8 x U
B
-
U
B
V DC
- Max. load
-
-
50
mA
Rated insulation voltage U
i
-
-
300
V
Rated impulse withstand voltage U
imp
-
-
1.5
kV
Resilience to vibration
In acc. with EN IEC 60947-5-2
Switching frequency
-
-
1
Hz
Repeat accuracy R
≤
10
%
EMC protection requirements
In accordance with EN IEC 60947-5-3 and EN IEC 61326-3-1
Reliability values acc. to EN ISO 13849-1
Category
4
Performance Level
PL e
PFH
d
4.1 x 10
-9
/ h
Mission time
20
years
1) Values at a switching current of 50 mA without taking into account the cable length.