About this document, Correct use, Operating instructions safety switch ces-ap-c01-ch – EUCHNER CES-AP-C01-CH (Multicode) User Manual
Page 3
Operating Instructions Safety Switch CES-AP-C01-CH
3
About this document
This document is valid for all safety switches CES-AP-C01-CH with version number
V 0.1.2 or higher.
Correct use
The Coded Electronic Safety switches series CES are safety devices for monitor-
ing movable safety guards.
In combination with a separating safety guard and the machine control, this safety
component prevents dangerous machine movements from occurring while the
safety guard is open. A stop command is triggered if the safety guard is opened
during the dangerous machine function.
Before safety switches are used, a risk assessment must be performed on the
machine, e.g., in accordance with:
Ì
EN ISO 13849-1, Safety of machinery. Safety related parts of control systems.
General principles for design
Ì
EN ISO 12100, Safety of machinery – General principles for design – Risk as-
sessment and risk reduction
Ì
IEC 62061, Safety of machinery. Functional safety of safety-related electrical,
electronic and programmable electronic control systems.
Correct use includes compliance with the relevant requirements for installation
and operation, for example
Ì
EN ISO 13849-1, Safety of machinery. Safety related parts of control systems.
General principles for design
Ì
EN 1088, Safety of machinery. Interlocking devices associated with guards.
Principles for design and selection
Ì
EN 60204-1, Safety of machinery. Electrical equipment of machines. General
requirements
Ì
EN 60947-5-3, Specification for low-voltage switchgear and controlgear. Con-
trol circuit devices and switching elements. Requirements for proximity devices
with defined behavior under fault conditions
The safety switch must be used only in conjunction with the designated CES ac-
tuators from EUCHNER. On the use of different actuators, EUCHNER provides no
warranty for safe function.
Important!
Ì
The user is responsible for the integration of the device into a safe overall
system. For this purpose, the overall system must be validated, e.g. in ac-
cordance with EN ISO 13849-2.
Ì
In the estimation of the PL for the overall system, a maximum value of
100 years can be assumed for the MTTF
d
according to the limit value in
EN ISO 13849-1:2008, section 4.5.2. This corresponds to a minimum value
for the PFH
d
of 2.47x10
-8
/h.
Ì
Correct use requires observing the permissible operating parameters (see
Technical data).
Ì
If a product data sheet is included with the product, the information on the
data sheet applies in case of discrepancies with the operating instructions.
Ì
It is only allowed to use components that are permissible in accordance with
the table below.