Operating Instructions Safety Switch CES-AP-C01-CH

12

Requirements for connection cables

Caution!

Risk of damage to equipment or malfunctions as a result of incorrect connec-
tion cables.

Ì

Use connection components and connection cables from EUCHNER

Ì

On the usage of other connection components, the requirements in the fol-
lowing table apply. EUCHNER provides no warranty for safe function in case
of failure to comply with these requirements.

Ì

Please observe the maximum cable length of 200 m.

Observe the following requirements with respect to the connection cables:

Parameter

Value

Unit

Conductor cross-section

0.34

mm²

R max.

60

W/km

C max.

120

nF/km

L max.

0.65

mH/km

Recommended cable type

LIYY 8x or 5x 0.34 mm²

Connector assignment, safety switch CES-AP-C01

Figure 1: Connector assignment, safety switch CES-AP

Pin

Plug connector

Designation

Description

Wire color as per

DIN 47100

8-pin

5-pin

5-pin,

pin 5

not

used

1

-

-

n.c.

Not used

white

2

1

1

UB

Power supply, DC 24 V

brown

3

2

2

OA

Safety output, channel 1

green

4

4

4

OB

Safety output, channel 2

yellow

5

5

-

DIA

Monitoring output

gray

6

-

-

n.c.

Not used

pink

7

3

3

0V

Ground, DC 0 V

blue

8

-

-

RST

Reset input for hardware reset

red

View on the connection side of the safety switch

Plug connector

8
2
7
6
1
3
4
5

UB
0V
n.c.
n.c.
OA
OB
DIA

RST

1
3

2
4
5

UB
0V

OA
OB
DIA

1
3

2
4
5

UB
0V

OA
OB
n.c.

8

3

5

7

4

2

1

6

3

5

4

1

2

8
2
7
6
1
3
4
5

UB
0V
n.c.
n.c.
OA
OB
DIA

RST

1
3

2
4
5

UB
0V

OA
OB
DIA

1
3

2
4
5

UB
0V

OA
OB
n.c.

8-pin

5-pin

8
2
7
6
1
3
4
5

UB
0V
n.c.
n.c.
OA
OB
DIA

RST

1
3

2
4
5

UB
0V

OA
OB
DIA

1
3

2
4
5

UB
0V

OA
OB
n.c.

8-pin

5-pin

5-pin, pin 5 not used