Operating Instructions Safety Switch CES-AP-C01-CH

17

Technical data

Note:

If a product data sheet is included with the product, the information on the data

sheet applies in case of discrepancies with the operating instructions.

Technical data for safety switch CES-AP-C01-CH

Parameter

Value

Unit

min.

typ.

max.

Housing material

PBT V0 GF30

Dimensions

According to EN 60947-5-2

Weight

0.4

kg

Ambient temperature at U

B

= DC 24 V

- 20

-

+ 55

°C

Storage temperature

- 25

-

+ 70

Degree of protection

acc. to EN IEC 60529

IP 67

Safety class

III

Degree of contamination

3

Installation position

Any

Connection

M12 plug connector, 8-pin or 5-pin

Operating voltage U

B

(reverse polar-

ity protected, regulated, residual

ripple < 5%)

24 ± 15% (PELV)

V DC

For the approval according to

the following applies

Operation only with UL Class 2 power supply, or equivalent

measures

Current consumption

50

mA

Switching load according to

DC 24 V, class 2

External fuse (operating voltage)

0.25

-

8

A

Safety outputs OA/OB

Semiconductor outputs, p-switching, short circuit-proof

- Output voltage U(OA)/U(OB)

1)

HIGH

U(OA)

U

B

-1.5

-

U

B

V DC

HIGH

U(OB)

LOW

U(OA)/U(OB)

0

1

Switching current per safety output

1

-

400

mA

Utilization category

according to EN IEC 60947-5-2

DC-13 24 V 400 mA

Caution: outputs must be protected with a free-wheeling diode in

case of inductive loads.

Off-state current

according to EN IEC 60947-5-2

(OA/OB)

2)

-

-

0.25

mA

Monitoring output DIA

1)

p-switching, short circuit-proof

- Output voltage

0.8 x U

B

-

U

B

V DC

- Max. load

-

-

200

mA

Rated insulation voltage U

i

-

-

300

3)

V

Rated impulse withstand voltage U

imp

-

-

1.5

kV

Resilience to vibration

In acc. with EN IEC 60947-5-2

Switching frequency

-

-

1

Hz

Repeat accuracy R

acc. to EN IEC 60947-5-2

≤ 10

%

EMC protection requirements

according to EN IEC 60947-5-3 and EN IEC 61326-3-1

Reliability values acc. to EN ISO 13849-1
Category

4

Performance Level

PL e

PFH

d

2.1 x 10

-9

/ h

Mission time

20

years

1) Values at a switching current of 50 mA without taking into account the cable length.
2) Maximum current at an output in switched-off state.
3) Tested by employers’ liability insurance association up to 75 V.