Operating Instructions Field Evaluation Unit CES-FD-AP-.-01-…

7

Mounting

Caution!

Risk of damage to equipment as a result of incorrect installation. The read head
must not be used as a mechanical end stop.

Ì

Fit an additional end stop for the movable part of the safety guard.

Important!

Ì

From the assured switch-off distance S

ar

, the safety outputs are safely shut

down.

Ì

When mounting several read heads, observe the stipulated minimum dis-
tance to avoid mutual interference.
- For CES-A-LMN s

min

= 20 mm

min. 20 mm

Note the following points:

Ì

Actuator, read head and field evaluation unit must be easily accessible for in-

spection and replacement.

Ì

The switching operation must only be triggered by the specific actuator desig-

nated for this purpose. For permissible combinations please see the table of

possible combinations on page 4.

Ì

Actuator and read head must be fitted so that

Ì

the front faces are at the minimum switch-on distance 0.8 x S

ao

or closer

when the safety guard is closed (see section Operating distances). A mini-

mum distance dependent on the actuator must be maintained for a side ap-

proach direction: - For CES-A-LMN

1.2 mm

Ì

when the safety guard is open up to the distance S

ar

(assured switch-off dis-

tance), a hazard is excluded.

Ì

the actuator is positively mounted on the safety guard.

Ì

pay attention to the maximum tightening torque for the field evaluation unit

mountings of 1 Nm.