Mounting, Mounting 7 – EUCHNER CES-FD-AP-U-01-xxx (Unicode) User Manual
Page 7
Operating Instructions Field Evaluation Unit CES-FD-AP-.-01-…
7
Mounting
Caution!
Risk of damage to equipment as a result of incorrect installation. The read head
must not be used as a mechanical end stop.
Ì
Fit an additional end stop for the movable part of the safety guard.
Important!
Ì
From the assured switch-off distance S
ar
, the safety outputs are safely shut
down.
Ì
When mounting several read heads, observe the stipulated minimum dis-
tance to avoid mutual interference.
- For CES-A-LMN s
min
= 20 mm
min. 20 mm
Note the following points:
Ì
Actuator, read head and field evaluation unit must be easily accessible for in-
spection and replacement.
Ì
The switching operation must only be triggered by the specific actuator desig-
nated for this purpose. For permissible combinations please see the table of
possible combinations on page 4.
Ì
Actuator and read head must be fitted so that
Ì
the front faces are at the minimum switch-on distance 0.8 x S
ao
or closer
when the safety guard is closed (see section Operating distances). A mini-
mum distance dependent on the actuator must be maintained for a side ap-
proach direction: - For CES-A-LMN
1.2 mm
Ì
when the safety guard is open up to the distance S
ar
(assured switch-off dis-
tance), a hazard is excluded.
Ì
the actuator is positively mounted on the safety guard.
Ì
pay attention to the maximum tightening torque for the field evaluation unit
mountings of 1 Nm.