Operating Instructions Field Evaluation Unit CES-FD-AP-.-01-…

20

Technical data CES-FD-AP-.-01…

Parameter

Value

Unit

min.

typ.

max.

Housing material

Plastic PBT

Dimensions

95 x 30 x 12

mm

Weight

0.04

kg

Ambient temperature at U

B

= DC 24 V

°C

- With connection cable with plug

connector M12
- Connection cable laid rigidly

- 20

-

+ 65

- Connection cable movable

- 5

-

+ 65

Degree of protection

IP 67

Safety class

III

Degree of contamination

3

Installation position

Any

Connection

- Evaluation

- Read head

Connection cable with plug connector M12x1, 5-pin

Connection cable with plug connector M8x1, 3-pin

Operating voltage U

B

(reverse polarity protected,

regulated, residual ripple < 5%)

1)

24 ± 15% (PELV)

V DC

For the approval according to

the following

applies

Operation only with UL Class 2 power supply, or equivalent measure

Current consumption

45

mA

External fuse (operating voltage)

0.25

-

8

A

Safety outputs FO1A/FO1B

Semiconductor outputs, p-switching, short circuit-proof

- Output voltage U(FO1A)/U(FO1B)

1)

V DC

HIGH

U(FO1A)

U

B

-1.5

-

U

B

HIGH

U(FO1B)

LOW

U(FO1A)/U(FO1B)

0

1

Switching current per safety output

1

-

150

mA

Utilization category according to EN IEC 60947-5-2

DC-13 24 V 150 mA

Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.

Off-state current I

r

0.25

mA

Monitoring output OD

Semiconductor output p-switching, short circuit-proof

- Output voltage

0.8 x U

B

-

U

B

V DC

- Max. load

-

-

50

mA

Rated insulation voltage U

i

-

-

75

V

Rated impulse withstand voltage U

imp

-

-

1.5

kV

Resilience to vibration

In acc. with EN IEC 60947-5-2

Switching frequency

-

-

1

Hz

Repeat accuracy R

10

%

EMC protection requirements

In acc. with EN IEC 60947-5-3

Reliability values acc. to EN ISO 13849-1
Category

4

Performance Level

PL e

PFH

d

4.5 x 10

-9

/ h

Mission time

20

years

1) The device tolerates voltage interruptions of up to 5 ms.
2) Values at a switching current of 50 mA without taking into account the cable length.