Operating Instructions Field Evaluation Unit CES-FD-AP-.-01-…
4
Important!
Ì
The user is responsible for the integration of the device into a safe overall
system. For this purpose, the overall system must be validated, e.g. in ac-
cordance with EN ISO 13849-2.
Ì
In the estimation of the PL for the overall system, a maximum value of 100
years can be assumed for the MTTF
d
according to the limit value in EN ISO
13849-1:2008, section 4.5.2. This corresponds to a minimum value for the
PFH
d
of 2.47x10
-8
/h.
Ì
Correct use requires observing the permissible operating parameters (see
Technical data).
Ì
If a product data sheet is included with the product, the information on the
data sheet applies in case of discrepancies with the operating instructions.
Ì
It is only allowed to use components that are permissible in accordance with
the table below.
Possible combinations for CES components
Field evaluation unit
Read head
Actuator
CES-A-BMB
077791
CKS-A-BK1-RD
113461
CES-FD-AP-M-…
CES-A-LMN-SC
077790
CKS-A-L1B-SC-SC
113130
Important: Key adapter
CKS must not be used as
a lockout mechanism in
combination with multi-
code evaluation.
CES-FD-AP-U-…
CES-A-LMN-SC
077790
CKS-A-L1B-SC-SC
113130
Key to symbols
Combination possible