beautypg.com

Possible combinations for ces components – EUCHNER CES-FD-AP-U-01-xxx (Unicode) User Manual

Page 4

background image

Operating Instructions Field Evaluation Unit CES-FD-AP-.-01-…

4

Important!

Ì

The user is responsible for the integration of the device into a safe overall
system. For this purpose, the overall system must be validated, e.g. in ac-
cordance with EN ISO 13849-2.

Ì

In the estimation of the PL for the overall system, a maximum value of 100
years can be assumed for the MTTF

d

according to the limit value in EN ISO

13849-1:2008, section 4.5.2. This corresponds to a minimum value for the
PFH

d

of 2.47x10

-8

/h.

Ì

Correct use requires observing the permissible operating parameters (see
Technical data).

Ì

If a product data sheet is included with the product, the information on the
data sheet applies in case of discrepancies with the operating instructions.

Ì

It is only allowed to use components that are permissible in accordance with
the table below.

Possible combinations for CES components

Field evaluation unit

Read head

Actuator

CES-A-BMB

077791

CKS-A-BK1-RD

113461

CES-FD-AP-M-…

CES-A-LMN-SC

077790

CKS-A-L1B-SC-SC

113130

Important: Key adapter

CKS must not be used as

a lockout mechanism in

combination with multi-

code evaluation.

CES-FD-AP-U-…

CES-A-LMN-SC

077790

CKS-A-L1B-SC-SC

113130

Key to symbols

Combination possible

This manual is related to the following products: