Figure 2: Switching elements and switching functions
Switching position:
Locked
Not locked
Version
TK1-528..
TK2-528..
min. 11 / max. 14
min. 2 / max. 5
TK1-538..
TK2-538..
Figure 3: Dimension drawing
40
30
144
45
Ш
10
Ш
16
29,8
7,3
11
50
15,5
59
Ш 5,3 ( 4x )
22
M20 x 1,5
42
16
207,5
8
26
16
22
32
M5 ( 4x )
TK1-...A...
Guard locking pin right
Mechanical release
both sides
Only for contact
separation
Stroke 8 mm
TK1-...C...
Guard locking pin left
40
30
144
45
Ш
10
29,8
Ш
16
7,2
59
15,5
50
Ш 5,3 ( 4x )
16
42
22
M20 x 1,5
207,5
8
26
16
22
32
M5 ( 4x )
Mechanical release
both sides
Only for contact
separation
Stroke 8 mm
Terminal
assignment,
plug connector
SR6
SR11
Ordinal numbers of
switching contacts
TK1-4131..
TK2-4131..
Detail A
Detail A
Detail A
Mechanical release
∅9,5
∅6,5
8
13
For triangular key
acc. to DIN 22417
Detail A
Mechanical release
∅9,5
∅6,5
8
13
For triangular key
acc. to DIN 22417