beautypg.com

Operating instructions safety switch tk, Figure 3: dimension drawing – EUCHNER TKxxx User Manual

Page 6

background image

Operating Instructions Safety Switch TK...

EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax +49/711/75 33 16 www.euchner.de [email protected]

Figure 2: Switching elements and switching functions

Switching position:

Locked

Not locked

Version

TK1-528..
TK2-528..

min. 11 / max. 14

min. 2 / max. 5

TK1-538..
TK2-538..

Figure 3: Dimension drawing

40

30

144

45

Ш

10

Ш

16

29,8

7,3

11

50

15,5

59

Ш 5,3 ( 4x )

22

M20 x 1,5

42

16

207,5

8

26

16

22

32

M5 ( 4x )

TK1-...A...

Guard locking pin right

Mechanical release
both sides

Only for contact
separation

Stroke 8 mm

TK1-...C...

Guard locking pin left

40

30

144

45

Ш

10

29,8

Ш

16

7,2

59

15,5

50

Ш 5,3 ( 4x )

16

42

22

M20 x 1,5

207,5

8

26

16

22

32

M5 ( 4x )

Mechanical release
both sides

Only for contact
separation

Stroke 8 mm

Terminal

assignment,

plug connector

SR6

SR11

Ordinal numbers of

switching contacts

TK1-4131..
TK2-4131..

Detail A

Detail A

Detail A

Mechanical release

∅9,5

∅6,5

8

13

For triangular key

acc. to DIN 22417

Detail A

Mechanical release

∅9,5

∅6,5

8

13

For triangular key

acc. to DIN 22417