beautypg.com

Operating instructions safety switches nx, Technical data – EUCHNER NXxxx User Manual

Page 6

background image

Operating Instructions Safety Switches NX...

Technical Data

Parameter

Value

Housing material

Die-cast alloy, cathodically dipped

Degree of protection accord-

ing to 60529 NX1...

IP67

Mech. Mechanical life

2x10

6

operations

Ambient temperature

-20 ... +80°C℉

Degree of contamination

(external, according to

EN 60947-1)

3 (industrial)

Installation position

Any

Approach speed, max.

20 m/min

Actuating force, max.

40 N

Extraction force

50 N

Retention force

10 N

Actuation frequency, max.

6700 / h

Switching principle

Slow-action switching contact

Contact material

Silver alloy, gold flashed

Connection type NX1...

Screw terminal

Conductor cross-section

(rigid/flexible) NX1...

0.34 mm² ... 1.5 mm²

Operating voltage for optional

LED indicator

L024 AC/DC 24 V +10%, -15%

Switching voltage, min.,

at 10 mA

12 V

Switching current, min.,

at 24 V

1 mA

Short circuit protection

(control circuit fuse)

according to IEC 60269-1

4 A gG

Conv. thermal current I

th

4 A

Utilization category

acc. to EN 60947-5-1

AC-15

DC-13

4 A 230 V

4 A 24 V

Rated impulse withstand

voltage

U

imp

= 2.5 kV

Rated insulation voltage

U

i

= 250 V

Conditional short-circuit

current

100 A

Reliability figures according to EN ISO 13849-1

B

10d

4.5 x 10

6