Verify the retrofit, Configure the cem3 – ETC Sensor+ Touring Rack CEM+ to CEM3 Retrofit User Manual
Page 15

2
The Retrofit
13
Verify the Retrofit
Step 1:
Put the dimmer modules back in the rack in the correct/original order.
Step 2:
Put the CEM3 in the rack making sure it is fully seated.
Step 3:
Power up the rack.
Step 4:
Check that the CEM3 powers up and the rack fan turns on. (The only rack errors
should be a lack of DMX on the ports if the DMX source is not present.)
Configure the CEM3
Step 1:
Configure the rack to reflect the dimmer module types installed. Verify that the
rack type is correct (CEM3 should have determined this from the DIP switch
settings - see
). Configuration of the CEM3 is done
using the front face panel interface. See the CEM3 Quick Guide that ships with
the CEM3 for more information.
Step 2:
Configure the data types that will be used (DMX and sACN) including the rack
patch.