Replace af cards (af racks only), Upgrading the rack door, Rack door replacement – ETC Sensor+ Touring Rack CEM+ to CEM3 Retrofit User Manual
Page 13

2
The Retrofit
11
Replace AF Cards (AF Racks Only)
If your touring rack supports Advanced Features (AF) you will need to replace the AF cards
as well.
AF cards are located on the right side of the dimmer module slot between the copper
neutral busses and the dimming circuitry cards.
To replace the AF cards:
Step 1:
Remove the old AF cards by flipping the white
retainer tab on the cards into the down
position.
Step 2:
Pull the old cards out of the slots.
Step 3:
Set the DIP switches on the new cards
according to the chart below (SP48 - #1-2;
SP96 - #1-4).
Step 4:
Slide the new AF cards completely into the
vacant slots starting with card #1 in the top left
slot. The number of cards depends on rack
size.
Step 5:
Flip the white tab up to lock the new card in
place.
Upgrading the Rack Door
Depending on the kit you ordered, you may be replacing the rack door or you may only be
replacing the baffle at the top of the existing door. If you are replacing the door, and your
old door has a cylindrical lock without a flip lever handle, you will need to remove that lock
and install it in the new door that you received. If you would like a new lock, you may
purchase one separately.
If your rack has the flip lever handle, you do not need to remove it. On these doors, only
baffle replacement is necessary.
Rack door replacement
Doors with curved baffles and cylindrical locks
will need to be replaced. The lock from the old
door must be removed and installed on the new
door. The new door will come with the required
baffle installed.
Step 1:
Remove the retention nut from the
lock using a 7/8” open end wrench
Step 2:
Continue loosening the nut while
sliding the lock assembly out through
the front of the door.
Flip tab down, pull card out
1
2
AF Card Addressing
Card 1
Card 2
Card 3
Card 4
S
W
1
S
W
2
S
W
3
S
W
4
Remove nut
Press to slide lock
through door