beautypg.com

Installing the hpl lamp, Hpl lamps, N o t e – ETC Source Four CE MultiPAR User Manual

Page 5: Warning

background image

English

Source Four MultiPAR CE 5

Installing the HPL lamp

Always replace the lamp if it becomes damaged or deformed. Use care installing the lamp. Improperly installed
lamps will cause premature lamp and socket failures.

1.

Disconnect power before installing the lamp.

2.

Let the lamp cool before replacing.

3.

Loosen the captured screw on the back of the raceway and open the raceway lid.

4.

The raceway lid is designed to remain open using gravity. If lid swings shut, reposition the MultiPAR unit using
the hanging irons or trunnions to lock the unit in position.

5.

Remove lamp socket by loosening the gnurled knob and removing the socket assembly. Remove the HPL
lamp from its box, holding it by the base.

6.

Insert lamp base into pin holes in socket assembly.

7.

Push down on the lamp base until the lamp is firmly inserted. Make sure that the lamp is fully seated, with the
bottom of the lamp heat sink flush to the socket assembly surface.

8.

To reinstall the socket assembly, insert until the heat sink base rests flush against the reflector, then tighten the
knurled bolt to secure the socket assembly in place. See (

Figure 1

)

N o t e :

To avoid premature lamp failure, do not touch the lamp glass with your fingers. If you touch the

lamp during installation, clean it carefully with rubbing alcohol and a clean, lint-free cloth before

operation.

HPL lamps

WARNING:

Use of other lamps may pose a safety risk, damage the fixture, and will void your warranty.

Lamp code

Watts Volts

Color temp Ave rated life

HPL 375/230X 375

230

3,000ºK

1,000 hours

HPL 375/240X 375

240

3,000ºK

1,000 hours

HPL 575/230

575

230

3,200ºK

400 hour

HPL 575/230X 575

230

3,050ºK

1500 hours

HPL 575/240

575

240

3,200ºK

400 hour

HPL 575/240X 575

240

3,050ºK

1500 hours

HPL 750/230

750

230

3,200ºK

300 hours

HPL 750/230X 750

230

3,050ºK

1500 hours

HPL 750/240

750

240

3,200ºK

300 hours

HPL 750/240X 750

240

3,050ºK

1500 hours

Lamp Base

Raceway Interior

Figure 1

Reflector

Socket Assembly