Circuit wiring configurations for the MultiPar-12.
The Source 4 MultiPAR CE can be wired for 3 circuit or 4 circuit configurations. Before changing the configuration,
make sure that you have sufficient power (dimmer capacity) to operate the fixture. There are four terminal blocks
inside the unit to place wiring. Each terminal block has four lead connection points. All of the hot and neutrals are
labeled with a number for your convenience.
Three circuit configuration
1.
Disconnect power before changing the wiring.
2.
Loosen the captured screw on the back of the raceway and open the raceway lid.
3.
In the first terminal block on the left, insert the wires labeled 1,4,7,10.
4.
In the second terminal block from the left, insert the wires labeled 2,5,8,11.
5.
In the third terminal block from the left, insert the wires labeled 3,6,9,12
6.
The fourth terminal block from the left is not used and is left empty.See
Figure 7
for detail.
Four circuit configuration
1.
Disconnect power before changing the wiring.
2.
Loosen the captured screw on the back of the raceway and open the raceway lid.
3.
In the first terminal block on the left, insert the wires labeled 1,5,9.
4.
In the second terminal block from the left, insert the wires labeled 2,6,10.
5.
In the third terminal block from the left, insert the wires labeled 3,7,11.
6.
In the fourth terminal block from the left, insert the wires labeled 4,8,12. See
Figure 7
for detail.