Before a swing cylinder can be manifold mounted, the port screw plugs and
copper gaskets must be removed.

The o-rings provided should be lubricated and installed in the counter-
bore around the port prior to mounting and bolting down the swing
cylinder.

Be sure that the o-ring does not get pinched or damaged during
mounting as leakage could result. To prevent leakage from the
manifold mounting, provide a fixture mounting surface with
flatness within 0,08 mm (0.003 in.) and a surface roughness not
to exceed Ra 1,6.

6.0 INSTALLATION

These Swing Cylinders are designed so that you can set the
position of the clamp arm after mounting the cylinder. If you need
to change the rotation direction, do it before mounting the
cylinder.

6.1 Changing Plunger Rotation (if needed)

5

Manifold Specifications

Cylinder Max.

Oil

Fixture

Mounting

Minimum

Lubricated

Manifold

Capacity

Channel

Hole

Threads

Thread

Mounting

O-Ring

Diameter

Diameter

Depth

Bolt Torque

Dimensions

Ø A

Ø B

C

D

I.D. x w

2,2 kN

4 mm

1.15 ± .03

M5

12 mm

4,5-5,4 Nm

6,07 x 1,78 mm

500 lb

0.156"

0.473"

40-48 in-lbs

0.239 x 0.070"

5,6 kN

4 mm

1.42 ± .03

M6

15 mm

12,2-14,9 Nm

7,65 x 1,78 mm

1250 lb

0.156"

0.591"

9-11 ft-lbs

0.301 x 0.070"

A

B

S

L

R

A

B

R

S

L

A

B

L

R

S

.25 "

(6,4mm)

6,4 mm

(0.25")

Clamp position

Unclamp port

Unclamp position

Clamp port

Clamp position

Clamp and

unclamp position

Unclamp

position

Unclamp port

Clamp port

Unclamp port

Clamp port

Retaining ring removed

from groove.

Plunger

Clamp
arm
bolt

Clamping

arm

Approximately

4 turns out.

Bottom plug

STRAIGHT

LEFT SWING

RIGHT SWING

Upper Flange

Remove port
screw plug.

O-ring

O-ring

Lower
Flange

Remove port
screw plug.