beautypg.com

Integrating the gold hawk on a pcb, Grounds and returns – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Hawk User Manual

Page 32

background image

Gold Hawk Installation Guide

Installation

MAN-G-HAKIG (Ver. 1.001)

www.elmomc.com

32

Figure 3: Gold Hawk External Heat Sink

4.5. Integrating the Gold Hawk on a PCB

The Gold Hawk is designed to be mounted on a PCB, either by soldering its pins directly to the
PCB or by using suitable socket connectors. Refer to the Gold Line Guitar Design Guide for
further information.

4.5.1.

Grounds and Returns

The returns in each functional block are listed below:

Functional Block

Return Pin

Power

PR (Power Return)

Internal Switch Mode P.S.

PR (Power Return)

Analog input return

ANLRET (J2/20)

Common return

COMRET (J2/25,31,32,43,46; J1/23)

STO safety signal return

STO_RET (J1/10)

Input Return

IN_RET (J1/3)

Table 8: Grounds and Returns

The returns above are all shorted within the Gold Hawk in a topology that results in optimum
performance.

Caution:
Follow these instructions to ensure safe and proper implementation. Failure to
meet any of the below-mentioned requirements can result in drive, controller
or host failure.

1.

When wiring the traces of the above functions, on the Integration Board, the Returns of

each function must be wired separately to its designated terminal on the Gold Hawk. DO
NOT USE A COMMON GROUND PLANE
. Shorting the commons on the Integration Board
may cause performance degradation (ground loops, etc.).