beautypg.com

Auxiliary supply, Environmental conditions – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Hawk User Manual

Page 21

background image

Gold Hawk Installation Guide

Technical Information

MAN-G-HAKIG (Ver. 1.001)

www.elmomc.com

21

3.1.1.

Auxiliary Supply

Feature

Details

Auxiliary power supply

Isolated DC source only

Auxiliary supply input voltage

14 to 95 VDC (100 V models)

23 to 195 (200 V models)

Auxiliary supply input power

≤ 5 VA without external loading

≤ 8 VA with full external loading

3.2. Environmental Conditions

Feature

Operation Conditions

Range

Ambient

Temperature

Range

Non-operating conditions -50 °C to +100 °C (-58 °F to 212 °F)

Operating conditions

-40 °C to +70 °C (-40 °F to 160 °F)

Temperature

Shock

Non-operating conditions -40 °C to +70 °C (-40 °F to 160 °F) within 3

min

Altitude

Non-operating conditions Unlimited

Operating conditions

-400 m to 12,000 m (-1312 to 39370 feet)

Maximum

Humidity

Non-operating conditions Up to 95% non-condensing humidity at 35 °C

(95 °F)

Operating conditions

Up to 95% non-condensing humidity at 25 °C
(77 °F), up to 90% non-condensing humidity
at 42 °C (108 °F)

Vibration

Operating conditions

20 Hz to 2000 Hz, 14.6g

Mechanical

Shock

Non-operating conditions ±40g; Half sine, 11 msec

Operating conditions

±20g; Half sine, 11 msec