Warnings, Cautions, Warnings 1.2. cautions – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Solo Hornet User Manual
Page 9
Gold Solo Hornet Installation Guide (EtherCAT and CAN)
Safety Information
MAN-G-SOLHORIG-EC (Ver. 1.009)
9
1.1. Warnings
•
To avoid electric arcing and hazards to personnel and electrical contacts, never
connect/disconnect the servo drive while the power source is on.
•
Power cables can carry a high voltage, even when the motor is not in motion. Disconnect
the Gold Solo Hornet from all voltage sources before it is opened for servicing.
•
The Gold Solo Hornet servo drive contains grounding conduits for electric current
protection. Any disruption to these conduits may cause the instrument to become hot (live)
and dangerous.
•
After shutting off the power and removing the power source from your equipment, wait at
least 1 minute before touching or disconnecting parts of the equipment that are normally
loaded with electrical charges (such as capacitors or contacts). Measuring the electrical
contact points with a meter, before touching the equipment, is recommended.
1.2. Cautions
•
The Gold Solo Hornet servo drive contains hot surfaces and electrically-charged
components during operation.
•
The maximum DC power supply connected to the instrument must comply with the
parameters outlined in this guide.
•
When connecting the Gold Solo Hornet to an approved isolated 12 to 95 VDC auxiliary
power supply, connect it through a line that is separated from hazardous live voltages using
reinforced or double insulation in accordance with approved safety standards.
•
Before switching on the Gold Solo Hornet, verify that all safety precautions have been
observed and that the installation procedures in this manual have been followed.
•
Do not clean any of the Gold Solo Hornet drive's soldering with solvent cleaning fluids of pH
greater than 7 (8 to 14). The solvent corrodes the plastic cover causing cracks and eventual
damage to the drive's PCBs.
Elmo recommends using the cleaning fluid Vigon-EFM which is pH Neutral (7).
For further technical information on this recommended cleaning fluid, select the link:
VIGON_EFM-US.pdf