Outputs, Inputs, Outputs 2.2.6. inputs – ElmoMC Gold Line Digital Servo Drives-Gold Solo Trombone User Manual
Page 15
Gold Solo Trombone Installation Guide
Product Description
MAN-G-SOLTROIG (Ver. 1.3)
15
2.2.5.
Outputs
• Four high voltage outputs related to VDD and VDDRET:
Conforms to IEC 61131-2
Up to 30 VDC
High side logic (Source)
Low side logic (Sink) - AP
Opto-isolated
For S, 0 suffix, Digital Outputs 2,3,4 up to 250 mA
For AP suffix, Digital Outputs 2,3,4 up to 150 mA
For T, 1 suffix, Digital Outputs 2,3,4 up to 7 mA
For S, 0 suffix, Digital Output 1 brake output: 500 mA
For AP suffix, Digital Output 1 brake output: 300 mA
For T, 1 suffix, Digital Output 1: 7 mA
Short circuit protection
Thermal protection
Reverse polarity protection
• Three additional differential outputs can be configured through Port C:
EIA-422 differential output line transmitters
Response time < 1μs
Output current: ± 15 mA
2.2.6.
Inputs
• Six Digital Inputs – optically isolated, sharing a single common INRET
• Six Digital Inputs - optically isolated sharing a single common positive supply - AP
• The six digital inputs can be configured to PLC or TTL, depending on the part number
definition
• All six inputs are fast capture data <5 μs
• One Analog Input: ±10 V
• Six additional fast differential event capture inputs 5 V logic cab be configured through
Ports A and B:
Via Port A or B (three on each port, depending on model)
EIA-422 Differential input line receiver
Response time < 1 μs