beautypg.com

Preset 10 architectural two - installation, Page 4 of 9, Wiring information – Doug Fleenor Design PRE10-A2 User Manual

Page 4: Power supply

background image

Page 4 of 9

Preset 10 Architectural Two - INSTALLATION

WIRING INFORMATION

Preset 10 Architectural Two is designed to use daisy-chain wiring topology. Unlike its predecessor the Preset 10
Architectural,
the Preset 10 Architectural Two has an input (TB2) and output (TB1) connector. Also note that a system
m ay contain m ultiple power supplies when voltage drop becom es a concern. Please give us a call if you have any
questions.

POWER SUPPLY

The voltage provided to the Preset 10 Architectural Two m ust be between 9-15 volts AC or DC. The Preset 10 Architectural
Tw o
has been designed to operate on a standard class 2 “doorbell” transform er. For exam ple Ace Hardware’s m odel#
ACE36483 10 volt 5 watt transform er.

Single M aster Installation
Note:

All jum pers installed

CABLE

COLOR

FROM

TO

USE

1

120 Ohm Data Cable
Belden 9829 or
Equivalent

Shield

5 Pin XLR Plate

Pin 1

PRE10-A2 Master

TB2-1

Common

White/Blue Stripe

Pin 2

TB2-2

Data -

Blue/White Stripe

Pin 3

TB2-3

Data +

2

(2) #16 AWG
Stranded Wires

Black

Power Supply

Common

TB1-4

Supply

Red

Power

TB1-5

Supply “hot”

3

120 Ohm Data Cable
Belden 9829 or
Equivalent

Shield

PRE10-A2 Master

TB1-1

Dimmer Cabinet

?

Common

White/Blue

TB1-2

?

Data -

Blue/White Stripe

TB1-3

?

Data +

Multi Master Installation
Note: Remove

JP5

CABLE

COLOR

FROM

TO

USE

1

120 Ohm Data Cable
Belden 9829 or
Equivalent

Shield

5 Pin XLR Plate

Pin 1

PRE10-A2 Master

Room 1

TB2-1

Common

White/Blue Stripe

Pin 2

TB2-2

Data -

Blue/White Stripe

Pin 3

TB2-3

Data +

2

(2) #16 AWG
Stranded Wires

Black

Power Supply

Common

TB1-4

Supply

Red

Power

TB1-5

Supply “hot”

3

120 Ohm Data Cable
Belden 9829 or
Equivalent

Shield

PRE10-A2 Master

Room 1

TB1-1

PRE10-A2 Master

Room 2

TB2-1

Common

White/Blue Stripe

TB1-2

TB2-2

Data -

Blue/White Stripe

TB1-3

TB2-3

Data +

4

(2) #16 AWG
Stranded Wires

Black

TB1-4

TB1-4

Supply

Red

TB1-5

TB1-5

Supply “hot”

5

120 Ohm Data Cable
Belden 9829 or
Equivalent

Shield

PRE10-A2 Master

Room 2

TB1-1

Dimmer Cabinet

?

Common

White/Blue

TB1-2

?

Data -

Blue/White Stripe

TB1-3

?

Data +