Chapter 4 main technical functions, Chapter 5 operation – DIGIWEIGH DWP-C2X User Manual
Page 5
2
◆ Power-saving mode and auto turn off function (Optional)
◆ Tare, hold, and accumulation functions
◆ Stable weighing, which will not be effected by shaking
◆ Convenient wireless remote can be operated within 20 meters for zeroing, record checking and
shutdown
◆ High heat insulation and anti erosion versions are available
Chapter 4 Main Technical functions
1、
Applicable temperature range: - 10
℃ ~ +40℃
2、
Relative Humidity:
≤90% RH
3、
Display: 5 digits super bright 1.2" LED digital tube (or LCD), letter highness 40mm
4、
New advanced high precision SCM with extremely strong magnetic resistant function and reliable
steady weighing.
5、
Gravity correction function makes it suitable for all over the world.
6、
Safe over-lifting: 150% F.S
7、
Damaging over-lifting: 200% F.S
8、
Steady reading: <5 seconds
9、
Precision: Grade III
10、
Zeroing range: ≤10%F.S
11、
Tare range: 10% ~ 100%
Chapter 5 Operation
5.1 Switch On/Off
5.1.1 Startup
Under "OFF" situation, press
“Tare On/Off" on the front panel, switch on and release the button when
the display shows on. It first shows" UEr6.0" of the copyright and self-check (showing figures 9-0) in
one second. (With decimal point, tare/stability lights flashing on), then it shows the battery capacity
percentage as
“pbt85", then it enters into zero reformat, showing"-----" (it will not show if the
reformatting has been completed after self-check).By the end of Zeroing it shows"0" or "0.0", entering
into weighing status
5.1.2 Shutdown
On switch-on regime, press button [Tare on/off] in the front panel or [
0
] on the remote for one
second, showing tAr-9, release the button and press again to display the battery capacity like [pbt85],
then release the button to automatically cut off power supply.
5.1.3 Energy saving mode and auto shutdown