beautypg.com

Appendix 1 glitch and self- maintenance – DIGIWEIGH DWP-C2X User Manual

Page 12

background image

9

Appendix 1 Glitch and self- maintenance

Error

Reason

Check method

Solution

Unable to startup


Battery

pack

damaged

Use power meter to measure the
voltage of the two ends of battery,
lower

than

5.0V

means

breakdown,

Replace battery

Bad connecting of
battery wire

Shake gently the connecting wire

Reconnect

or

weld

the

battery wire

On/Off

button

damaged

Open the front panel and the two
ends behind the short-circuit
on/off button can be startup.

Replace the On/Off button

Charger indicator
does not light

Charger damaged


Connect through the power, the
charger light not on, voltage meter
shows less than 8V output

Replace charger

Charger not plug on

Less than 8V output, check the
plug connecting

Re-plug on the charger

No electricity on the
socket or not press
down

the

socket

button

Use Volt meter to check if the
socket light is on

Replace

to

socket

with

electricity or press down the
button

Battery can not be
charged up

Battery damaged

8V output of the charger but no
voltage going up after connected

Replace the battery

Plug damaged

Sometimes it works when shake
the charger connector

Replace the charger

Short battery life

Not

our

charger,

Long-term

damage

to

the

battery

over-voltage charge.

Check if the output power is more
than 8V

Replace the charger, our
company's charger output is
7.4-7.8

Battery

Lifetime

expired

The voltage drops down fast after
charging up

Replace the battery

Self-discharge
caused by bad seal

Battery polarity welding is not
sealed or water in battery pack by
poor sealed.

Seal the battery welding area
and the battery case by glue.

Unstable display

Items

shake

seriously

while

weighing

Intensely shaking or over shaking

Wait till it is stable

The

transfer

is

damaged by over
loaded

or

the

insulation

is

damaged

The output and input of the
transfer change too much or the
value is 1 when use Voltage meter
at 20MQ

Replace the transfer with the
manufacturer.