- 12 -

kg or lb is selectable. The unit of weighing is kg normally. You can change it to lb by
pressing and holding 【﹡】key 2 seconds at least.

17 Connection to Mini-printers

Connect serial port printer Type Up-16TS as follows:

Indicator Serial Port Printer
9 pin hole 25 pin needle
3 TXD 2
5 GND 7

Note: Before connection to printer, communication address is set as Adr=01; baud rate is
set as b=2400.
Print operation with serial port printer is as follows:
17.1.Print: at weighing status, weighing data >20d and display is stable, press 【∴】,

weighing sheet is printed out. The second printing can be operated only when the
weighing data is back to <20d.

17.2 Accumulated print: at weighing status, press 【﹡】, then press 【∴】, accumulated

printing can be operated.

17.3 Set to be automatic accumulation status, i.e. automatic print.

At weighing status, weighing data>20d and display is stable, weighing sheet is printed
out. The second printing can be operated only when the weighing data is back to
<20d and more weight is loaded.
Attached with print sample
Normal print accumulation print
NO:1 (serial No.) NO: 9 (number of accumulation)
Gross: 3940kg (gross weight) W: 8225kg (accumulated weight)
Tare: 2000kg (tare weight)
Net: 1940kg (net weight)

18 Precaution

·Indicator should be far away from heat resource while using.
·Do not place the indicator in the dusty surroundings or the site vibrant.
·Cannot use full capacity. Over load stops hitting platform support is not permitted.
·To ensure to keep out of chemical erosion, Operating temperature range will be

–10-50℃,relative humidity is no less than 85%,without any corrupt gas in air.

·Never pour the water into the indicator.
·Housing, head pallet, wire connector should be sealed entirely. Users do not open sealed

device or connect with wire without any expert advice. In case any malfunction of indicator
occurs, please sent the indicator for maintenance.

·The indicator will charge the internal battery at all times when it is connected to the main

power.