DW-PJ Pallet Jack Scale

- 10 -

Press【﹡】

〖AUt 0〗

the selection of manual/automatic accumulation

AUt = 0, manual accumulation

AUt = 1, automatic accumulation and print when weight is added,
〖AUTO〗indicator is lit.

AUt=2,automatic memorize displayed value when weight is added.

Accumulate and print final stable values after load down to below

20d.
〖AUTO〗indicator is lit.

AUt=3,dynamic weighing method. At weighing >20d: the buzzer

sounds “du”and lock is displayed for 6 seconds. When a new

data is fixed, lock is displayed again for 6 seconds. Then lock

is released for weighing <20d; automatic accumulation and

print. Suggest FLt>30, 〖AUTO〗indicator is lit.

AUt=4, peak value fixed weighing method. At weighing>20d, the
buzzer sounds“du”and lock is displayed.
When weighing <20d, fixed data displays with flash,

automatic accumulation and print. Lock can be released by pressing

any key. 〖AUTO〗indicator is lit.

AUt=5, dynamic weighing method. Manual accumulation and print.

AUt=6, peak value fixed weighing method. Manual accumulation and

print.

AUt=7, counting function. ★note

3

Press【↑】

〖AUt 0〗

digit displays with flash

4

Press【↑】

Press【↑】

Press【↑】

〖AUt 0〗
〖AUt 1〗
〖AUt 2〗
〖AUt 3〗

Sets F·S

Move binking digit to the right bit

e.g. AUt=3 expresses dynamic weighing method

5

Press【﹡】

〖 0〗

return to normal weighing status

note: (1) sampling: When net weight on scale is zero (tare can be removed by pressing
tare key if net weight is not zero), the sample , which must be <200 pieces, i.e. between 1
to 199, is put on the scale. Press 【→】and 【↑】, input quantity of the sample (e.g.30),
〖Cnt030〗 is displayed. Press 【﹡】, confirm the completion of sampling. Weighing status
is redisplayed. Sampling is memorized even with power off.

Step

operation

display

description

1

place sample

place selected sample, weight: 27, quantity:30

2

press 【 → 】

press 【→】

〖 Cnt000 〗
〖Cnt000〗

ready to input sample’s quantity

decimal digit display with flash

3

press【↑】

press【↑】

press【↑】

〖Cnt010〗
〖Cnt020〗
〖Cnt030〗

4

press 【﹡】

〖 27〗

display sample’s weight:27, 【*】is a confirmation key, sample collection

This manual is related to the following products: