DIGIWEIGH DWP-PJ-P User Manual
Page 10
![background image](/manuals/557891/10/background.png)
DW-PJ Pallet Jack Scale
- 9 -
Pressed【﹡】key three times during calibration or configuration, The indicator will display.
To view the A/D counts, press the 【→】key when 〖-A-d-〗is displayed
press the【
﹡
】key to return to weighing mode.
8 Zero
When the weight is stable, Press 【→0←】key for two seconds to set the zero point and
zero the display. the 【→0←】status LED is turned on.
9 Tare
9.1
Digital tare
press【→】key , set tare with【→】and【↑】key , then press【→0←】key , the input data
is tare , Tare status LED is turned on.
9.2
Acquire tare
When Tare status LED is off and the weight is stable, press the 【→0←】key to acquire
tare and switch to net mode. The Tare status LED is turned on.
9.3
Remove tare
When Tare status LED is on, press【→0←】key will switch to gross mode and removed
tare. The Tare status LED is off.
10 Manual weight accumulation
When weight is stable, press【∴】key to accumulation the current weight to the total
weight, The total number of accumulation will be displayed for 〖n 12〗1.5 seconds.
11 High resolution display mode
In this display mode , press 【↑】, switch to high resolution display mode. (10 times
normal display) The last decimal point is light on. Press【↑】key return to normal weight
display mode.
12 Automatic Memory Accumulation
Selection of manual/automatic accumulation function (Selection of manual /automatic print
function). Selection of animal scale, peak value retain and counting function.
Step
Operation
Displaying
Contents
1
Press【﹡】
〖n 12〗
to display times of accumulation