beautypg.com

14 how to set datum, 15 battery capacity, 16 unit of weighing – DIGIWEIGH DWP-PJ-P User Manual

Page 12: Kg and lb

background image


DW-PJ Pallet Jack Scale

- 11 -

completed

5

press【↑】

〖C 30〗 display sample’s quantity, 【↑】is change-over key between weight and

quantity display

(2) Counting operation: place the object on scale, weight is displayed, press【↑】,

〖C 255〗is displayed, and the display changes over to the quantity of the object. When

the display is stable, press 【∴】, accumulate the weight and quantity. Accumulation can
be done only at counting status.

Step

operation

display

description

1

place object

〖 230〗

object weight:230

2

press【↑】

〖C 255〗

object quantity:255

3

press 【∴】

〖n 4〗
〖C 255〗

display after 1.5 seconds

at counting status

(3) accumulate inquiries and delete: both at weighing stage and counting status

Step

operation

display

description

1

press 【﹡】

〖C 1203〗 display the total quantity of the object:1203

2

press【↑】

〖H 0〗 display accumulated weight 4 digits higher

3

press【↑】

〖L 1085〗 display accumulated weight 4 digits lower=1085

4

press【↑】

〖C 1203〗 back to counting status

5

press【→0←】 〖C 0〗 delete accumulated quantity

13 Clear memory

Press【→0←】key If the memory has previously been cleared the display will show
〖n 0〗followed by zero weight when the【﹡】key is pressed.

14 How to set datum

Press【→】key move and blinks the current digit to.
Press【↑】key increment the current digit to the next available value

15 Battery capacity

When the indictor is being power on/off.battery capacity will be displayed
〖PBt 85〗for1.5 seconds
·When the battery is capacity less than 20%,the display will start to blink, power off the

indictor to avoid over discharging battery or connect the external main. Power supply

·When the battery capacity ≤ 10%,the indictor automatic turn off to avoid

battery over discharge

·In auto power off mode, If weight is stable and no key operation for more than >3 mints,

The indictor displays 〖- 〗to conserve battery

·When auto power off setting is action, If weight is stable and no key operation > 30

mints automatic turn off power

·A full charged battery life is approximately 30 hours

16 Unit of weighing:

(

kg and lb

)

This manual is related to the following products: