6.9. Quick setting
Press [SET] to get quick setting parameter ,Press [TARE] to enter and
[M+] and [RECALL] to shift :
PARA, including time, date, back light, auto power off , key beep, unit ,
CHECK , setting checking beep mode, same as mentioned in 5.4
RS232, setting RS232 parameter , same as mentioned in 5.4
RECHARGE setting : To check the currency when charging(mA)
Count : 1) calibration count value; 2)parameter set count value,
Quit setting by press [ZERO]