DIGIWEIGH DWP-800 DWP-102E Indicator User Manual
Page 3

- 2 -
SECTION 1 INTRODUCTIONS
1.1 Introduction
The indicator provides an accurate, fast and versatile series of general purpose weighing indicator with counting, check-weighing,
animal weighing functions and preset tare.
1.2 Specification
Housing
plastic housing
Power supply
110V 50/60Hz
built-in rechargeable battery. 6V4AH.
Display
6 digits 1
’LED.
Max input
15mV
ADC
Σ-Δ
External
Resolution
1/30000
Interface
RS-232 Output
Stabilisation time
1 second typical
Operating
temperature
0°C - 50°C / 32°F - 104°F
Load
cell
drive
voltage
5V/ Max 150mA
Other function
Real-time clock and units conversion
Load cells
Up to eight 350 ohms cells
1.3 Installation
The weighing indicator should be sited in a location accuracy would not be degraded.
Avoid extremes of temperature.
Avoid unstable power sources. Do not use near large users of electricity such as welding equipment or large motors.
Verify the voltage showing on the label matches the voltage in your area.
connection of loadcell:
Plastic housing connect to Din9
Pin6 +E
Pin1 -E
Pin9 +S
Pin8 -S
Pin5 shield
connection of RS232
Plastic housing connect to Din9 Pin 2 TXD Pin3 RXD Pin5 GND
SECTION 2 KEY DESCRIPTIONS
SOFT POWER ON/OFF Key
Power on/off the indicator.
ZERO Key
1) When self-checking, Press ZERO Key to enter parameter setting;
2) Set the zero point for all-subsequent weighing;