Main specification – DIGIWEIGH DWP-800 DWP-102E Indicator User Manual
Page 2
- 1 -
Main Specification
1. Model
:
DWP-440 bench shipping/counting scale
2. Accuracy:
Grade
Ⅲ, n=3000
3. Sample Rate
:
10 times / second
4. Load cell sensitivity
:
1.5
~3mV / V
5. Scale interval
:
1/2/5/10/20/50 for option
6. Display
:
6 bits LCD
,6 state indicating signals
7. Scoreboard interface (optional)
:
In serial output mode
:current loop signal,
transmission distance≤50m,
8. Communication interface (optional)
:RS232C;Baud rate 1200/2400/4800/9600 optional
9. Power supply:
Battery DC6V/4AH
10. Operating temperature/humidity:
0
~40℃;≤90%RH
11. transporting temperature:
-20
~50℃
This manual is related to the following products: