12
0
°
15
°
45
°
15
°
30
°
30
°
DETECTOR VERTICAL FIELD OF VIEW
WITH DETECTOR AT 45
°
FROM HORIZONTAL.
0
°
15
°
15
°
30
°
45
°
30
°
45
°
150
ft
150
ft
120
ft
120
ft
90
ft
90
ft
60
ft
60
ft
30
ft
210
ft
210
ft
180 ft
180
ft
Figure 9A—Field of View at Indicated Distance in Feet for Gasoline
at Very High Sensitivity
0
°
15
°
30
°
45
°
15
°
30
°
45
°
100 ft
90 ft
90 ft
80 ft
80 ft
50 ft
50 ft
40 ft
40 ft
30 ft
20 ft
10 ft
0
°
15
°
45
°
15
°
30
°
30
°
DETECTOR VERTICAL FIELD OF VIEW
WITH DETECTOR AT 45
°
FROM HORIZONTAL.
70 ft
70 ft
60 ft
60 ft
100 ft
30 ft
20 ft
10 ft
Figure 9B—Field of View at Indicated Distance in Feet for Methane
at Very High Sensitivity
0
°
15
°
30
°
45
°
15
°
30
°
45
°
150 ft
135 ft
120 ft
75 ft
60 ft
45 ft
30 ft
15 ft
105 ft
90 ft
Figure 9C—Field of View at Indicated Distance in Feet for
Methanol at Very High Sensitivity
0
°
15
°
15
°
30
°
45
°
30
°
45
°
150
ft
120
ft
90
ft
60
ft
30
ft
210
ft
180
ft
Figure 9E—Field of View at Indicated Distance in Feet for
JP-5 at Very High Sensitivity
0
°
15
°
30
°
45
°
15
°
30
°
45
°
150 ft
135 ft
120 ft
75 ft
60 ft
45 ft
30 ft
15 ft
105 ft
90 ft
Figure 9D—Field of View at Indicated Distance in Feet for
Diesel at Very High Sensitivity
0
°
15
°
30
°
45
°
15
°
30
°
45
°
100 ft
90 ft
80 ft
50 ft
40 ft
30 ft
20 ft
10 ft
70 ft
60 ft
Figure 9F—Field of View at Indicated Distance in Feet for Gasoline
at Medium Sensitivity
- GP16XX Standard Gas Panel (20 pages)
- EQP Fire and Gas Detection/Releasing System (157 pages)
- STB Series Sensor Termination Box and Separation Kit (4 pages)
- NTMOS IP66/IP67 H2S Gas Detector (19 pages)
- UD20 FlexVu Explosion-Proof Universal Display Unit (15 pages)
- UD10 DCU Emulator FlexVu Universal Display Unit (71 pages)
- UD10 FlexVu Explosion-Proof Universal Display Unit (77 pages)
- UD10 FlexVu Universal Display SAFETY MANUAL (6 pages)
- PIRECL Infrared Carbon Dioxide Gas Detector PointWatch Eclipse (54 pages)
- FlexSonic Acoustic Detector (37 pages)
- FlexSonic Acoustic Detector SAFETY MANUAL (6 pages)
- GT3000 Series Electrochemical Gas Detector (26 pages)
- GT3000 Series Electrochemical Gas Detector SAFETY MANUAL (6 pages)
- PIRECL Infrared Hydrocarbon Gas Detector PointWatch Eclipse (69 pages)
- PIRECL Infrared Hydrocarbon Gas Detector PointWatch Eclipse SAFETY MANUAL (8 pages)
- PIR9400 PointWatch Infrared Hydrocarbon Gas Detector (34 pages)
- 505 Combustible Gas Detector Transmitter with Combustible Gas Sensor CGS (27 pages)
- PIRVOLLT Volumetric Infrared Hydrocarbon Gas Process Monitor for Light Hydrocarbons (18 pages)
- PIRVOLHV Volumetric Infrared Hydrocarbon Gas Process Monitor for Heavy Hydrocarbons (18 pages)
- PIRVOLVR Volumetric Infrared Hydrocarbon Gas Process Monitor for Vapor Recovery Systems (18 pages)
- X9800 IR Flame Detector (31 pages)
- X9800 IR Flame Detector with Pulse Output (32 pages)
- X2200 UV SIL 2 Certified Flame Detectors SAFETY MANUAL (6 pages)
- X5200 UVIR Flame Detector (35 pages)
- X5200 UVIR Flame Detector with Pulse Output (36 pages)
- X5200 UVIR Flame Detector with HART (21 pages)
- X3302 Multispectrum IR Flame Detector (37 pages)
- X3302 Multispectrum IR Flame Detector with Pulse Output (36 pages)
- X3302 Multispectrum IR Flame Detector with HART (21 pages)
- X3302 Multispectrum IR Flame Detector SAFETY MANUAL (8 pages)
- X3301 Multispectrum IR Flame Detector (40 pages)
- X3301 Multispectrum IR Flame Detector with Pulse Output (39 pages)
- X3301 Multispectrum IR Flame Detector with HART (21 pages)
- X3301 Multispectrum IR Flame Detector with Automotive (2 pages)
- X2200 UV Flame Detector (32 pages)
- X2200 UV Flame Detector with Pulse Output (33 pages)
- X2200 UV Flame Detector with HART (21 pages)
- OPECL Infrared Hydrocarbon Gas Detector (49 pages)
- OPECL Infrared Hydrocarbon Gas Detector SAFETY MANUAL (6 pages)
- U9500 Infiniti Gas Transmitter (50 pages)
- U5006 Air Duct Smoke Detector (8 pages)
- U5005 Smoke Detector (4 pages)
- EQ3750ASH EQP Addressable Smoke & Heat (ASH) Module (8 pages)
- PM-5MPX Dual Spectrum IR (17 pages)
- EQP Fire and Gas Detection/Releasing System SAFETY MANUAL (28 pages)