Replace high limit instrument, Danger – Despatch LBB2-xxA/B-1 User Manual
Page 49
LBB Series Oven Owner’s Manual
M
AINTENANCE
Version 15
49
Copyright © 2012 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
6.5.2.
Replace High Limit Instrument
Danger!
Do not attempt any service on this oven before opening the
main power disconnect switch.
Tools needed:
One-quarter (1/4) inch socket set
Screwdriver
T20 Torx bit driver
1. Disconnect power.
2. Remove four screws from the face of the control panel (
3. Slide the panel forward (
4. Remove wires from the old High Limit instrument, carefully noting which wires
connect to which terminals (
5.
Disconnect High Limit instrument connector from circuit board (Figure 18).
6.
Disconnect the thermocouple wires (Figure 15).
7.
Press and hold down the tabs holding the High Limit instrument to the control panel and slide
it out (Figure 19).
High Limit
Connector
Block
Figure 18. High Limit Connector Block on Control Board.