beautypg.com

Replace high limit instrument, Danger – Despatch LBB2-xxA/B-1 User Manual

Page 49

background image

LBB Series Oven Owner’s Manual

M

AINTENANCE

Version 15

49

Copyright © 2012 by Despatch Industries.

All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any

means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and

retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.

6.5.2.

Replace High Limit Instrument

Danger!

Do not attempt any service on this oven before opening the

main power disconnect switch.

Tools needed:

One-quarter (1/4) inch socket set

Screwdriver

T20 Torx bit driver

1. Disconnect power.

2. Remove four screws from the face of the control panel (

Figure 13

).

3. Slide the panel forward (

Figure 14

).

4. Remove wires from the old High Limit instrument, carefully noting which wires

connect to which terminals (

Figure 15

).

5.

Disconnect High Limit instrument connector from circuit board (Figure 18).

6.

Disconnect the thermocouple wires (Figure 15).

7.

Press and hold down the tabs holding the High Limit instrument to the control panel and slide

it out (Figure 19).

High Limit

Connector

Block

Figure 18. High Limit Connector Block on Control Board.

This manual is related to the following products: