Temperature – Despatch LBB2-xxA/B-1 User Manual
Page 13
LAC Series Oven Owner’s Manual
A
BOUT
T
HIS
M
ANUAL
Version 15
13
Copyright © 2012 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
1.5.4.
Temperature
Temperature and
Parameters
LBB Model Number
1-23
1-43
1-69
2-12
2-18
2-27
Time to
temperature
(approximate
minutes with no
load
40°C-
150°C
17
17
15
15
17
17
40°C-
204°C
30
30
26
30
33
33
Recovery time with
door open 1 minute
(approximates
minutes with no
load)
150°C
2
2
3
3
3
4
204°C
4
4
6
6
7
8
Temperature
uniformity at:
150°C +/- 3°C +/- 3°C +/- 3°C +/- 2°C +/- 3°C
+/- 3°C
204°C +/- 4°C +/- 4°C +/- 4°C +/- 3°C +/- 4°C
+/- 4°C
Operating range with 20°C
ambient:
35°C- 204°C
40°C-204°C
Control Stability
± 0.5 °C
Dampers must be open to operate at the minimum
temperature.
“Time to Temperature” and “Temperature Uniformity”
values are based on 240V/60 Hz operation, with control
panel located on top. Actual results may vary slightly
depending on unit configuration and operating conditions.