beautypg.com

Temperature – Despatch LBB2-xxA/B-1 User Manual

Page 13

background image

LAC Series Oven Owner’s Manual

A

BOUT

T

HIS

M

ANUAL

Version 15

13

Copyright © 2012 by Despatch Industries.

All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any

means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and

retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.

1.5.4.

Temperature

Temperature and

Parameters

LBB Model Number

1-23

1-43

1-69

2-12

2-18

2-27

Time to

temperature

(approximate

minutes with no

load

40°C-

150°C

17

17

15

15

17

17

40°C-

204°C

30

30

26

30

33

33

Recovery time with

door open 1 minute

(approximates

minutes with no

load)

150°C

2

2

3

3

3

4

204°C

4

4

6

6

7

8

Temperature

uniformity at:

150°C +/- 3°C +/- 3°C +/- 3°C +/- 2°C +/- 3°C

+/- 3°C

204°C +/- 4°C +/- 4°C +/- 4°C +/- 3°C +/- 4°C

+/- 4°C

Operating range with 20°C

ambient:

35°C- 204°C

40°C-204°C

Control Stability

± 0.5 °C

Dampers must be open to operate at the minimum

temperature.

“Time to Temperature” and “Temperature Uniformity”

values are based on 240V/60 Hz operation, with control

panel located on top. Actual results may vary slightly

depending on unit configuration and operating conditions.

This manual is related to the following products: