Operation Instructions
To Operate the Running Line Tensiometer Safely and efficiently, the user must have a working
knowledge of the Condux CableGlider Puller.
!WARNING: Read and Understand the “Cableglider User’s Guide and Safety
Manual” before operating the CableGlider Cable Puller or Running Line
Tensiometer.
EQUIPMENT PREPARATION
1. Verify that the rope is properly inserted in the sheave grooves
2. Manually tension the rope.
3. Verify that the Mechanical Sensing Unit does not interfere with the cable puller Frame
4. Turn the Electronic Control Box power switch to ON.
5. Verify that the tension limit has been set correctly
6. Verify that the tension limit control is ON, if overload control is required.
7. Verify that Chart Recorder has been set to record, if desired.
CABLE PULLING PROCEDURES
1. Press the foot switch to start the puller. Slowly remove any slack or excess pull line.
Attend the line coming off the capstan to avoid any tangles, and keep some tension on the
line so that the capstan grips the pull line.
2. Stand at least 3 to 4 feet (0.9 to 1.2 m) away and at a 30 degree angle from the cable
puller capstan. Wear gloves to avoid rope burns and abrasions.