Chart recorder set up – Condux Running Line Tensiometer User Manual
Page 13

13
Limiter switch is in the “ON” position the puller will stop pulling when the tension limit
is reached (See Figure 10)
Chart Recorder Set Up
The Digital Chart Recorder is the next generation Solid State Data Recorder/Panel Recorder.
This instrument has all the capability of a traditional paper recorder – variable chart speeds, the
ability to review historic data, see trends and more. All pull data is stored on the 64MB Compact
Flash Card that comes with the unit.
1. Name File Press “MENU” button to enter the Menu screen. Use ▲ and ▼ arrows to
scroll to RECORD MODE and press menu. Next, scroll to “NAME FILE”
and press
MENU. Use the ▲ and ▼ buttons to scroll through letters and the ◄ and ► buttons to
move spaces. (See Figures 11-14). Once the name is set press “MENU” button to go
back to Record Mode. From Record Mode, ◄ or ► will return to Menu screen.
Pressing ◄ or ►again will return to charting screen.
Figure 10
Figure 11