Comelit MT 3451 FR User Manual
Page 21

21
VALUE IN SECS
10
SCROLL
OK
ESC
CANC
AUDIO TIME
010
DOOR LOCK TIME
02
RESET WAIT TIME
10
SIMPLEBUS
TYPE
*AC
AC PLUS
DC
OK
OK
SCROLL
ESC
TYPE
AC
PLUS
CONFIRMATION TONE
STANDBY LOCK REL.
ACTUATOR FUNCTION
ACTIVATION TIME
03
IN PARALLEL TO SE
EN
2.2.1.2 ENTER DOOR LOCK TIME
2.2.1.3 ENTER RESET TIME
RANGE = 1 - 8 sec.
RANGE = 1 - 10 sec.
4. Confi rm.
4. Confi rm.
4. Confi rm.
1. Access programming mode, see page 17.
2. Select:
settings/system parameters/speaker
parameters/door lock time.
3. Enter the desired value:
1. Access programming mode, see page 17.
2. Select:
settings/system parameters/speaker
parameters/reset time.
3. Enter the desired value.
2.2.1.4 VIEW
1. Access programming mode, see page 17.
2. Select:
settings/system parameters/speaker
parameters/view.
» Reproduces the parameter values: audio time, door
lock time and reset time.
2.2.1.5 ADVANCED OPTIONS
A) TYPE
2.2.1.5.1 LOCK ON SE
Allows setting of the door lock type on the SE output of
the speaker module
3. Choose between:
4. Confi rm.
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/lock on SE/type.
AC (default)
AC PLUS
DC
B) CONFIRMATION TONE
Allows enabling/disabling of the door lock confi rmation
tone on the speaker module
4. Confi rm.
3. Choose between:
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/lock on SE/confi rmation tone.
YES
NO
C) STANDBY LOCK REL.
D) VIEW
Allows enabling/disabling of the standby lock release on
the speaker module
Allows viewing of the door lock parameters on the SE
output of the speaker module
4. Confi rm.
3. Choose between:
» Reproduces the parameter values: type, confi rmation tone,
standby lock release.
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/lock on SE/standby lock rel.
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/lock on SE/view.
YES (default)
NO
4. Confi rm.
4. Confi rm.
2.2.1.5.2 RELAY CONTACT
A) ACTUATOR FUNCTION
B) IN PARALLEL TO SE
C) VIEW
Allows enabling/disabling of the actuator function on the
relay contact
Allows enabling/disabling of the relay contact in parallel
to the speaker module SE output
Allows viewing of the relay contact parameters
3. Choose between:
3. Choose between:
» Reproduces the relay contact parameters.
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/relay contact/actuator function.
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/relay contact/in parallel to SE.
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/relay contact/view.
YES
NO
YES
NO