Peak Ovens
4
MF15 – 3.13
The supply MUST incorporate an earth (ground).
CONNECTION DETAILS
supply type
Supply
Terminal label
Cable colour
Live-Neutral
Reversible or Live-Live
1-phase
L
Brown
To live
to either power conductor
N
Blue
To neutral
to the other power conductor
PE
Green/Yellow
To earth (ground)
to earth (ground)
2- or 3-ph
L1
Black
to phase 1
L2
Black
to phase 2
L3
Black
to phase 3 except 2-phase
N
Light Blue
to neutral except delta
PE
Green/Yellow
to earth (ground)
DO NOT connect an oven ordered for three phase use to a single phase supply or to the wrong type
of three phase supply.
* stoving and curing, or other special options: always check the rating label for the correct
amperage, as there may be an increase in power above the standard model.