beautypg.com

Circuit diagrams – Carbolite Peak Series User Manual

Page 11

background image

Peak Ovens

7.0 C

IRCUIT

D

IAGRAMS

7.1 Single Phase (overtemperature control: none or hydraulic thermostat)

7.2 Single Phase (overtemperature control: digital)

7.3 Two-phase with Neutral

As 3-phase with neutral (7.4), but with phase L3 not present, and with two SSRs and element
circuits.

Note on Hydraulic Thermostat. When used over 16 Amps or in a 2- or 3-phase
model, the oven is fitted with a contactor, with the hydraulic thermostat in the coil
circuit – similar to 7.2.

Instrument Switch

temperature

controller

SSR

e

l

e

m

e

n

t

(s)

F1

F2

N

L

PE

Filter

thermocouple

Hydraulic

thermostat

Warning light

Hydraulic

t/stat o/temp

only

Reset

button

Fan motor

Fan models

only

coil

Instrument Switch

temperature

controller

SSR

e

l

e

m

e

n

t

(s)

F1

F2

N

L

PE

Filter

thermocouple

Fan motor

Fan models

only

overtemp.

controller

thermocouple

relay or

contactor