beautypg.com

Automa! on products group, inc – APG MNU Slave Sensor user manual User Manual

Page 34

background image

MNU Series Ultrasonic Sensors

Rev. B1, 5/13

34

Automa! on Products Group, Inc.

APG...Providing tailored solu• ons for measurement applica• ons

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

Type 6: n/a

Type 7 (Loss of Echo): the relay will ac! vate if the sensor enters a loss of echo condi! on (no targets detected).

Type 8 n/a

Type 9 (Rate of Change): allows the user to defi ne a maximum rate of change (distance over ! me), which if

exceeded will ac! vate an alarm. The Trip Distance parameter is used to defi ne the ! me value, and the Trip

Window parameter is used to defi ne the distance value.

Trip

Distance

Trip
Window

Empty

Distance

Zero Reference

Point

ON

ON

Trip Type 1
;ĞdžĐůƵƐŝǀĞͿ

OFF

(Increasing)

ON

Trip Type 2
(hysteresis near)

OFF

OFF

(Decreasing)

ON

OFF

ON

Trip Type 4
;ŝŶĐůƵƐŝǀĞͿ

OFF

OFF

(Decreasing)

ON

OFF

(Increasing)

Trip Type 5
(hysteresis far)

ON

ON

OFF

Trip Type 3
(far)

ON

OFF

Trip Type 0
(near)

This manual is related to the following products: