APG MNU Slave Sensor user manual User Manual
Page 11

Rev. B1, 5/13
MNU Series Ultrasonic Sensors
11
Automa! on Products Group, Inc.
APG...Providing tailored solu• ons for measurement applica• ons
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
(con! nued)
Register
Func! on
Value Range
40408
Sensi! vity
0 to 100
40409
Pulses
0 to 20
40410
Blanking
0 to 10364 mm
40411
Gain Control
0 to 4
40412
Averaging
0 to 100
40413
Filter Window
0 to 10364 mm
40414
Out of Range Samples
0 to 255
40415
Sample Rate
50 to 1000 msec.
40416
Mul! plier
1 to 1999
40417
Off set
+/- 10364 mm
40418-40419
reserved
n/a
40420
Temperature Compensa! on
0 = off , 1 = on
40421-40435
reserved
n/a
40436-40437
Parameter 1 Data
0 to 100,000 mm
40438-40439
Parameter 2 Data
0 to 100,000 mm
40440-40441
Parameter 3 Data
0 to 100,000 mm
40442-40443
Parameter 4 Data
0 to 100,000 mm
40444-40445
Parameter 5 Data
0 to 100,000 mm