APG MNU Slave Sensor user manual User Manual
Page 27

Rev. B1, 5/13
MNU Series Ultrasonic Sensors
27
Automa! on Products Group, Inc.
APG...Providing tailored solu• ons for measurement applica• ons
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
Applica! on Type 11: Curve Fit (Strapping Chart)
Allows the sensor to mimic a tank strapping chart by using a 3rd degree polyno-
mial equa! on to produce a “curve fi t” approxima! on.
(measurement result in register 30303-30304)
Register
Func! on
Value Range
40401
Units
1 to 3
40402
Applica! on Type
11
40404
Decimal Place
0 to 3
40406
Full Distance
Typically = Blanking
40407
Empty Distance
0 to 10364 mm
40436-40437
Parameter 1
0 to 100,000 mm
40438-40439
Parameter 2
0 to 100,000 mm
40440-40441
Parameter 3
0 to 100,000 mm
40442-40443
Parameter 4
0 to 100,000 mm
Open the APG Modbus so# ware and select “Strapping Chart” from the “Tools”
menu.
Enter the desired data points
into the table.
Use the “Load” bu$ on to re-
call a previously saved table.
Import data from an electronic
document by copying the data
and then using the “Paste”
bu$ on to populate the table.
OR