beautypg.com

APG MNU Slave Sensor user manual User Manual

Page 27

background image

Rev. B1, 5/13

MNU Series Ultrasonic Sensors

27

Automa! on Products Group, Inc.

APG...Providing tailored solu• ons for measurement applica• ons

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

Applica! on Type 11: Curve Fit (Strapping Chart)

Allows the sensor to mimic a tank strapping chart by using a 3rd degree polyno-
mial equa! on to produce a “curve fi t” approxima! on.

(measurement result in register 30303-30304)

Register

Func! on

Value Range

40401

Units

1 to 3

40402

Applica! on Type

11

40404

Decimal Place

0 to 3

40406

Full Distance

Typically = Blanking

40407

Empty Distance

0 to 10364 mm

40436-40437

Parameter 1

0 to 100,000 mm

40438-40439

Parameter 2

0 to 100,000 mm

40440-40441

Parameter 3

0 to 100,000 mm

40442-40443

Parameter 4

0 to 100,000 mm

Open the APG Modbus so# ware and select “Strapping Chart” from the “Tools”
menu.

Enter the desired data points
into the table.

Use the “Load” bu$ on to re-
call a previously saved table.

Import data from an electronic
document by copying the data
and then using the “Paste”
bu$ on to populate the table.

OR

OR

This manual is related to the following products: