INSTALLING GUY WEBS BEFORE INSTALLING FABRIC

ATTACH GUY WEBS TO EAVE WELDMENTS AND
STAKE OUT AT 45º. SEE STAKING GUIDELINES
ON PAGE 9.

X-CABLED BAYS

STAKE PLATES AT PROPER SPACING BEFORE
INSTALLING THE X-CABLES. THEN, ADJUST
TURNBUCKLES UNTIL CABLE IS SNUG

REMOVE NUTS FROM THE BOLTS THAT PIN THE
BASEPLATE TO THE UPRIGHT. TURN BOLTS SO THE
THREADS ARE TO THE INSIDE (TOWARD CENTER OF
BAY). THREAD CABLE EYE NUTS ONTO BOLTS TO
SECURE THE CABLE.

NAVI-TRAC UNITS 100 FT. OR MORE IN LENGTH MUST HAVE AN X-CABLED
BAY NEAR THE MIDDLE OF THE UNIT (AND/OR EQUALLY SPACED) FOR
EVERY 100 FT. UNIT OF LENGTH.

SUBSTITUTE BOLTS FOR PINS AT THE
TOP OF BOTH UPRIGHTS AND BOT-
TOM OF BOTH RAFTERS. THREADS
SHOULD POINT INWARD TOWARD
CENTER OF BAY. THREAD CABLE EYE
NUTS ONTO EACH BOLT TO SECURE
THE CABLES AS SHOWN.

FOR CABLE CONNECTIONS AT MID
PORTION OF RAFTERS, INSERT THE
BOLTS IN THE HOLES OF THE RAF-
TER THAT ARE JUST BELOW THE
PURLIN CONNECTION. THREADS
SHOULD POINT INWARD TOWARD
CENTER OF BAY. THREAD CABLE
EYE NUTS ONTO EACH BOLT TO
SECURE THE CABLES AS SHOWN.

PURLIN

X-CABLING IS IDENTICAL
ON BOTH SIDES OF THE
STRUCTURE.

RAFTER X-CABLES ARE
COLOR-CODED RED
AND LABELED 10, 15, OR
20 ACCORDING TO BAY
SIZE.

UPRIGHT X-CABLES ARE COLOR-
CODED GREEN AND LABELED 10,
15, OR 20 ACCORDING TO BAY
SIZE.

*

IMPORTANT NOTE:

REFER TO CAUTION STATEMENT #2 FOR IMPORTANT WARNING ABOUT NUMBER OF STAKES

SUPPLIED. (SEE BACK PAGE OF THIS MANUAL)

THE INSTALLER MUST USE THE LOCAL SOIL CONDITIONS TO CALCULATE THE ACTUAL NUMBER OF
STAKES REQUIRED AND IS RESPONSIBLE FOR THE STAKING PATTERN AND CONFIGURATION.

ANCHOR

PROVIDES ANCHORING PACKAGES FOR COMMON SOIL CLASSIFICATIONS; CONTACT YOUR TENT SALES REPRESENTATIVE
FOR MORE INFORMATION.

13