JLG 40RTS ANSI Service Manual User Manual
Page 67
![background image](/manuals/552409/67/background.png)
SECTION 3 - TROUBLESHOOTING
3120691
– JLG Sizzor –
3-3
Platform raises and lowers erratically
Hydraulic system low
Replenish hydraulic oil as required
Restricted or broken hydraulic line or fitting
Clean, repair or replace line or fitting
Lack of lubricant on lift cylinder attach pins
Lubricate as required (Refer to lubrication chart)
Counterbalance valve on lift cylinder improperly
adjusted or not functioning properly
Replace valve
Control valve not functioning properly
Repair or replace valve
Sizzor arm pins not properly lubricated
Lubricate as necessary
Worn seals in lift cylinder
Replace seals
Cylinder not functioning properly
Repair or replace lift cylinder
Platform drifts down
Manual lowering valve not functioning properly
Repair or replace valve
Worn seals in lift cylinder
Replace seals
Holding valve on lift cylinder not functioning prop-
erly
Repair or replace holding valve
High drive does not operate below set height
Damaged wiring on limit switch
Repair or replace wiring
Damage limit switch
Replace limit switch
Flow control valve not functioning properly
Repair or replace flow control valve
Flow control valve not properly set
Reset flow control valve
Table 3-1. Platform Assembly - Troubleshooting
TROUBLE
PROBABLE CAUSE
REMEDY