JLG 40RTS ANSI Service Manual User Manual
Page 50
SECTION 2 - PROCEDURES
2-34
– JLG Sizzor –
3120691
10.
Repeat steps 1-9 to assemble and install the two
remaining cluster gears.
11.
Set carrier assembly on work surface so that large
ends of cluster gears face up. Locate punch marks
on face of each cluster gear and position them at 12
o’clock as shown in diagram below.
12.
With “X-marked side facing up, place ring gear
around cluster gears.
NOTE: This will hold punch marks in position while installing
carrier into hub.
13.
Place carrier assembly and ring gear together into
mesh with internal gear, aligning “X”-marked shoul-
der bolt in ring gear over one of the shoulder bolt
holes in hub. Mark location of shoulder bolt holes on
outside of ring gear and hub.
NOTE: Ring gear may be lifted off hub to align shoulder bolt
holes. Ring gear and carrier were installed together
only to keep punch marks on carrier in place.
14.
Oil all exposed surfaces inside hub. Place thrust
washer into counter bore in top of carrier assembly .
Assemble cover as follows:
1.
Using disconnect rod, push o-ring into groove inside
cover cap.
2.
Place o-ring onto cover cap so it rests against flange
of cover cap.