SECTION 6 - JLG CONTROL SYSTEM
3121616
– JLG Lift –
6-35
H & T LIGHTS:
14
0
1
NO: No head and tail lights installed.
YES: Head and tail lights installed.
0
CABLE SWITCH:
15*
0
1
NO: No broken cable switch installed.
YES: Broken cable switch installed.
0
* Certain market selections will alter default setting.
LOAD SYSTEM:
16*
0
1
2
3
4
NO: No load sensor installed.
WARN ONLY: Functions in creep, overload lamp lit, platform alarm beeps (5
sec ON, 2 sec OFF).
CUTOUT PLATFORM: All functions cutout, overload lamp lit, platform alarm
beeps (5 sec ON, 2 sec OFF).
CUTOUT ALL: All functions cutout, flash overload light (500mS on, 500mS
off ), platform alarm beeps (5 sec ON, 2 sec OFF).
SPECIAL 1: Functions in creep, overload lamp lit, disables main telescope out
& main lift up, platform alarm beeps (5 sec ON, 2 sec OFF).
0
* Only visible under certain market selections.
* Certain market selections will limit load system options or alter default setting.
LOAD SENSOR:
17*
0
1
1 ON ROTATOR: Use the on-board load sensor for all models except those
which use the Leveling Platform Module.
4 UNDER PLATFORM: Use the EIM for load sensing.
1
* Only visible under certain market selections.
* Certain market selections will limit load system options or alter default setting.
Table 6-5. Machine Configuration Programming Information
Configuration Digit
Number
Description
Default
Number