beautypg.com

Level sensor, Flashing light, Sandblast protection kit – Snorkel AB80J User Manual

Page 38: Structures, Weldments, Warning

background image

Chapter 7 – Prestart Inspection

34

AB80J/AB85J – 0420453

5. Pull the level sensor to the side as far as possible to

activate the tilt alarm.

Warning

The potential for an accident increases when safety

devices do not function properly. Death or serious

injury can result from such accidents. Do not alter,

disable, or override any safety device.

6. If the alarm does not sound, remove the machine

from service until the problem is corrected.

7. Lower the main boom.

Flashing Light

If the machine is equipped with an optional flashing light,

visually check to see that it flashes. The light should flash

when the engine is running.

Sandblast Protection Kit

The optional sandblast protection kit protects the cylinders

from abrasion while sandblasting or from paint overspray.

Rubber covers protect each cylinder rod as it extends

and retracts. The covers prevent sand and paint from

damaging the cylinder seals and rod.

Inspect the covers while operating the machine to ensure

they are securely fastened and completely cover the cyl-

inder rod. Make sure there are no holes in the covers.

Structures

Visually inspect all weldments and related components.

It is important to inspect the fasteners that connect the

components.

Weldments

Visually inspect all weldments for abnormal wear, abra-

sion, or deformation that could cause interference be-

tween moving parts.

Inspect the welds on the structural components. Pay par-

ticular attention to boom welds. The area to be inspected

should be clean and free of dirt and grease. Look for

visible cracks in the weld and at the weld to parent mate-

rial joint. A bright light may be used to provide adequate

visibility of the inspection area.

Level Sensor

Figure 7.13 – Manual Emergency Lowering Pump

4. Pull and hold the riser boom knob outward while

pumping to lower the riser booms. Stop pumping and

release the knob to stop descent of the booms.

5. Pull and hold the riser boom knob outward while

pumping to lower the main boom. Stop pumping and

release the knob to stop descent of the booms.

6. Place the pump handle back in its holder.

Level Sensor

Use the following procedure to test the level sensor.

1. Position the aerial platform on a smooth, flat, level

surface.

2. Remove all persons and materials from the plat-

form.

3. Start the engine and raise the main boom above

horizontal, approximately 15 to 20 degrees.

4. Open the door on the left side of the machine to ac-

cess the level sensor (refer to Figure 7.14).

Figure 7.14 – Level Sensor

Pump

Manual Emergency

Lowering Pump

Main Boom Knob

Riser Boom Knob